Model |
MMHP9D1 |
MMHP12D1 |
MMHP15D1 |
MMHP22D1 |
MMHP12D3 |
MMHP15D3 |
MMHP22D3 |
||
|
Tensioni i shënuar / Frekuenca |
V~ / Hz |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
380–415 V / 3N~ / 50 Hz |
380–415 V / 3N~ / 50 Hz |
380–415 V / 3N~ / 50 Hz |
|
|
Ngrohje¹ |
Kapaciteti |
kW |
2.92-9.10 |
4.10-12.1 |
4.30-15.20 |
7.24-21.90 |
4.10-12.1 |
4.30-15.20 |
7.24-21.90 |
|
Fuqia e hyrjes |
kW |
0.61-2.11 |
0.79-2.85 |
0.87-3.73 |
1.50-5.88 |
0.79-2.85 |
0.87-3.73 |
1.50-5.88 |
|
|
Rrjedha e hyrjes |
A |
2.80-9.25 |
3.45-13.04 |
4.02-16.38 |
6.86-30.25 |
1.62-4.57 |
1.78-6.04 |
2.82-9.16 |
|
|
Ngrohje² |
Kapaciteti |
kW |
2.99-8.16 |
4.05-12.15 |
4.25-14.55 |
6.36-19.45 |
4.05-12.15 |
4.25-14.55 |
6.36-19.45 |
|
=DISPIMG("ID_72CEC376135E4DD8A9C17E7AACA46EC2",1) |
Fuqia e hyrjes |
kW |
1.03-2.92 |
1.38-4.06 |
1.45-4.28 |
2.15-6.85 |
1.38-4.06 |
1.45-4.28 |
2.15-6.85 |
|
Rrjedha e hyrjes |
A |
4.57-12.79 |
5.73-17.7 |
6.71-18.80 |
9.84-30.12 |
2.70-6.43 |
2.84-6.78 |
3.71-10.60 |
|
|
Ftohje |
Kapaciteti |
kW |
1.38-5.70 |
3.65-7.35 |
3.65-11.04 |
4.55-17.20 |
3.65-8.59 |
3.65-11.04 |
4.55-17.20 |
|
Fuqia e hyrjes |
kW |
0.67-2.44 |
1.12-2.87 |
1.12-3.97 |
1.85-7.31 |
1.12-3.31 |
1.12-3.97 |
1.85-7.31 |
|
|
Rrjedha e hyrjes |
A |
3.06-10.27 |
5.18-13.13 |
5.18-17.44 |
8.47-32.1 |
1.97-5.25 |
1.97-6.30 |
2.99-11.26 |
|
|
EER |
w/W |
2.06-2.34 |
2.56-3.26 |
2.78-3.26 |
2.35-2.88 |
2.60-3.25 |
2.78-3.26 |
2.35-2.46 |
|
|
SCOP (Temperatura e ujit në 35 °C) ℃) |
4.98 |
4.90 |
4.9 |
4.91 |
4.90 |
4.9 |
4.93 |
||
|
SCOP (Temperatura e ujit në 55 °C) ℃) |
3.84 |
3.86 |
3.86 |
3.94 |
3.86 |
3.86 |
3.93 |
||
|
Larg Aktiv Energji |
kW |
3.5 |
5.4 |
5.4 |
7.5 |
5.85 |
5.85 |
10.5 |
|
|
RRYSHI I KRAHUT TË KRAHUT |
A |
15 |
25 |
25 |
35 |
10 |
10 |
17 |
|
|
Lloji i Refrigierantit/Tarifë/GWP |
.../kg |
R290/0.55/3 |
R290/1.05/3 |
R290/1.05/3 |
R290\/1.4\/3 |
R290/1.05/3 |
R290/1.05/3 |
R290\/1.4\/3 |
|
|
CO2 Ekuivalent |
/ |
0.0017t |
0,0032 t |
0,0032 t |
0.0042t |
0,0032 t |
0,0032 t |
0.0042t |
|
|
Shtypje Larg (Anë Larg) |
MPa |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
|
|
Shtypje Larg (Anë Larg) |
MPa |
3 |
3.0 |
3 |
3 |
3.0 |
3 |
3 |
|
|
Shtypja Maksimale Lejore |
MPa |
3 |
3.0 |
3 |
3 |
3.0 |
3 |
3 |
|
|
I refraktuar nga Larg dhe Larg |
/ |
Unë |
Unë |
Unë |
Unë |
Unë |
Unë |
Unë |
|
|
Klasa IP |
/ |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
|
|
Expansion Tank |
L |
6L |
6L |
6L |
6L |
6L |
6L |
6L |
|
|
Temperatura Maksimale e Ujit në Larg |
℃ |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
|
|
Temperatura ambientale e funksionimit |
℃ |
-25~45 |
|||||||
|
Lidhjet e kanalizimit të ujës |
inç |
G1 |
G1 |
G1 |
G1-1⁄4 |
G1 |
G1 |
G1-1⁄4 |
|
|
Flusit e ujës normale |
m³/h |
1 |
2.06 |
2.06 |
3.1 |
2.06 |
2.06 |
3.1 |
|
|
Largimi i Shtypjes së Ujit |
kPA |
20 |
20 |
25 |
60 |
20 |
25 |
60 |
|
|
Shtypje ujore Min/Max |
MPa |
0.1/0.3 |
|||||||
|
Nivel Larg |
dB(A) |
43 |
50 |
50 |
45 |
50 |
50 |
45 |
|
|
Përmasat Nete ( G×L×L ) |
mm |
1187*418*805 |
1287*448*904 |
1287*448*904 |
1187*488*1455 |
1287*448*904 |
1287*448*904 |
1187*488*1455 |
|
|
Përmasat Nete ( G×L×L ) |
mm |
1217*463*920 |
1317*493*1020 |
1317*493*1020 |
1217*538*1570 |
1317*493*1020 |
1317*493*1020 |
1217*538*1570 |
|
|
Pesha Netë |
kg |
110 |
134 |
134 |
195 |
134 |
134 |
195 |
|
|
Pesha Bruto |
kg |
122 |
146 |
146 |
208 |
146 |
146 |
208 |
|
|
Kushtet e Testimit të Vlerësuara: Ngrohje¹: Temperatura Ambientale 7 ℃/6℃(DB/WB), Temperatura e Hyrjes/Daljes së Ujit 30 ℃/35℃ Ngrohje²: Temperatura Ambientale 7 ℃/6℃(DB/WB), Temperatura e Hyrjes/Daljes së Ujit 47 ℃/55℃ Ftohtësi: Temperatura Ambientale 35 ℃/24℃(DB/WB), Temperatura e Hyrjes/Daljes së Ujit 12 ℃/7℃ |
|||||||||
● Ndërtesat komerciale
Hoteleri, apartamente dhe ndërtesa zyri: Siguron ngrohje qendrore, ftohje qendrore dhe ujë të ngrohtë të përdorimit të përditshëm 24/7, duke ulur efektivisht konsumin e energjisë ditore dhe koston e punës së operacioneve.
Dyqane dhe klube: Punon me zhurmë ekstremisht të ulët për të ruajtur një ambient biznesi të qetë dhe të këndshëm, ndërkohë që plotëson nevojat e vazhdueshme dhe të këndshme të kontrollit të temperaturës.

● Instalimet industriale dhe publike
Fabrikat dhe depozitat: Ofron ngrohje të besueshme në dimër dhe mbrojtje kundër ngrirjes së pajisjeve, si dhe ftohje në verë për të përmirësuar kushtet e përgjithshme të punës për stafin.
Shkollat, spitalet dhe shtëpitë e pleqve: Sistem i qëndrueshëm dhe i besueshëm i kontrollit të klimës që siguron komoditet dhe siguri të vazhdueshme në të gjitha zonat publike.

● Projekte të mëdha rezidenciale dhe komunitare
Vilat dhe shtëpitë me shumë katete: Zgjidhje komplekse për ngrohjen, ftohjen dhe ujin e ngrohtë të shtëpisë, duke rritur në mënyrë të konsiderueshme komoditetin dhe cilësinë e përgjithshme të jetës.
Komunitetet rezidenciale: Mbështet lidhjen paralele të shumë njësive për të realizuar sisteme qendrore të ngrohjes me energji të pastër në nivel rajonal.
● Skenari të specializuar
Projekte të ruajtjes së nxehtësisë sipas stinëve: Përshtatet me veprimin e gjatë kohës në temperaturë të ulët, duke përdorur efikasistisht energjinë diellorë dhe burimet e tjera të energjisë së ripërtëritshme.
Projekte rishikimi: Zëvendëson boilerët tradicionale dhe kondicionerët pa ndryshime të mëdha në tubacione, duke lejuar përditësime të shpejta dhe të lëmuara të energjisë me emisione të ulëta karboni.