Model |
MMHP9D1 |
MMHP12D1 |
MMHP15D1 |
MMHP22D1 |
MMHP12D3 |
MMHP15D3 |
MMHP22D3 |
||
|
Nominaal spanning / Frekwensie |
V~ / HZ |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
220–240 V~ / 50 Hz |
380–415 V/3N~/50 Hz |
380–415 V/3N~/50 Hz |
380–415 V/3N~/50 Hz |
|
|
Verwarming¹ |
Kapasiteit |
kw |
2.92-9.10 |
4.10-12.1 |
4.30-15.20 |
7.24-21.90 |
4.10-12.1 |
4.30-15.20 |
7.24-21.90 |
|
Invoerkrag |
kw |
0.61-2.11 |
0.79-2.85 |
0.87-3.73 |
1.50-5.88 |
0.79-2.85 |
0.87-3.73 |
1.50-5.88 |
|
|
Invoerstroom |
A |
2.80-9.25 |
3.45-13.04 |
4.02-16.38 |
6.86-30.25 |
1.62-4.57 |
1.78-6.04 |
2.82-9.16 |
|
|
Verwarming² |
Kapasiteit |
kw |
2.99-8.16 |
4.05-12.15 |
4.25-14.55 |
6.36-19.45 |
4.05-12.15 |
4.25-14.55 |
6.36-19.45 |
|
=DISPIMG("ID_72CEC376135E4DD8A9C17E7AACA46EC2",1) |
Invoerkrag |
kw |
1.03-2.92 |
1.38-4.06 |
1.45-4.28 |
2.15-6.85 |
1.38-4.06 |
1.45-4.28 |
2.15-6.85 |
|
Invoerstroom |
A |
4.57-12.79 |
5.73-17.7 |
6.71-18.80 |
9.84-30.12 |
2.70-6.43 |
2.84-6.78 |
3.71-10.60 |
|
|
Koeling |
Kapasiteit |
kw |
1.38-5.70 |
3.65-7.35 |
3.65-11.04 |
4.55-17.20 |
3.65-8.59 |
3.65-11.04 |
4.55-17.20 |
|
Invoerkrag |
kw |
0.67-2.44 |
1.12-2.87 |
1.12-3.97 |
1.85-7.31 |
1.12-3.31 |
1.12-3.97 |
1.85-7.31 |
|
|
Invoerstroom |
A |
3.06-10.27 |
5.18-13.13 |
5.18-17.44 |
8.47-32.1 |
1.97-5.25 |
1.97-6.30 |
2.99-11.26 |
|
|
EER |
w\W |
2.06-2.34 |
2.56-3.26 |
2.78-3.26 |
2.35-2.88 |
2.60-3.25 |
2.78-3.26 |
2.35-2.46 |
|
|
SCOP (Water temperatuur by 35 ℃) |
4.98 |
4.90 |
4.9 |
4.91 |
4.90 |
4.9 |
4.93 |
||
|
SCOP (Water temperatuur by 55 ℃) |
3.84 |
3.86 |
3.86 |
3.94 |
3.86 |
3.86 |
3.93 |
||
|
Nominele invoerkrag |
kw |
3.5 |
5.4 |
5.4 |
7.5 |
5.85 |
5.85 |
10.5 |
|
|
GESKATTE INVOER STROOM |
A |
15 |
25 |
25 |
35 |
10 |
10 |
17 |
|
|
Koelmiddel Tipe/Inlading/GWP |
.../kg |
R290\/0.55\/3 |
R290\/1.05\/3 |
R290\/1.05\/3 |
R290\/1.4\/3 |
R290\/1.05\/3 |
R290\/1.05\/3 |
R290\/1.4\/3 |
|
|
CO2 Ekwivalent |
/ |
0.0017t |
0,0032 t |
0,0032 t |
0.0042t |
0,0032 t |
0,0032 t |
0.0042t |
|
|
Bedryfsdruk (Lae Kant) |
MPa |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
0.8 |
|
|
Bedryfsdruk (Hoë Kant) |
MPa |
3 |
3.0 |
3 |
3 |
3.0 |
3 |
3 |
|
|
Maksimum Toelaatbare Druk |
MPa |
3 |
3.0 |
3 |
3 |
3.0 |
3 |
3 |
|
|
Elektriese Schokevry |
/ |
I |
I |
I |
I |
I |
I |
I |
|
|
IP klas |
/ |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
|
|
Uitsettingsborsel |
L |
6L |
6L |
6L |
6L |
6L |
6L |
6L |
|
|
Maks. Uitstroomwater Temperatuur |
℃ |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
|
|
Bedryfsomgewings temperatuur |
℃ |
-25~45 |
|||||||
|
Waterpypingverbindinge |
duim |
G1 |
G1 |
G1 |
G1-1⁄4 |
G1 |
G1 |
G1-1⁄4 |
|
|
Geregistreerde waterstroom |
m³/h |
1 |
2.06 |
2.06 |
3.1 |
2.06 |
2.06 |
3.1 |
|
|
Waterdruk Val |
kPA |
20 |
20 |
25 |
60 |
20 |
25 |
60 |
|
|
Min(Max) waterdruk |
MPa |
0.1/0.3 |
|||||||
|
Geluidsniveau |
dB(A) |
43 |
50 |
50 |
45 |
50 |
50 |
45 |
|
|
Netto Afmetings ( L×W×H ) |
mm |
1187*418*805 |
1287*448*904 |
1287*448*904 |
1187*488*1455 |
1287*448*904 |
1287*448*904 |
1187*488*1455 |
|
|
Netto Afmetings ( L×W×H ) |
mm |
1217*463*920 |
1317*493*1020 |
1317*493*1020 |
1217*538*1570 |
1317*493*1020 |
1317*493*1020 |
1217*538*1570 |
|
|
NET Gewig |
kg |
110 |
134 |
134 |
195 |
134 |
134 |
195 |
|
|
Bruto gewig |
kg |
122 |
146 |
146 |
208 |
146 |
146 |
208 |
|
|
Gespesifiseerde toetsvoorwaardes: Verwarming¹: Omgewingstemperatuur 7 ℃/6℃(DB/WB), Water-in/uit-temperatuur 30 ℃/35℃ Verwarming²: Omgewingstemperatuur 7 ℃/6℃(DB/WB), Water-in/uit-temperatuur 47 ℃/55℃ Afkoeling: Omgewingstemperatuur 35 ℃/24℃(DB/WB), Water-in/uit-temperatuur 12 ℃/7℃ |
|||||||||
● Handelsgeboue
Hotelle, Woonstelle en Kantoorgeboue: Verskaf gesentraliseerde verhitting, verkoeling en 24/7 huishoudelike warmwater, wat daagliks energieverbruik en bedryfskoste vir arbeid effektief verminder.
Winkels en Klubs: Ultra-stil bedryf handhaaf 'n stil, aangename besigheidomgewing terwyl dit konsekwente en gerieflike temperatuurbeheerbehoeftes bevredig.

● Industriële en Openbare Fasiliteite
Fabrieke en Pakhuise: Verskaf betroubare winterverhitting en beskerming van toerusting teen vriesbeskadiging, asook somerverkoeling om die algemene werkomstandighede vir personeel te verbeter.
Skole, Hospitale en Sielkundige Woonfasiliteite: 'n Stabiele, betroubare klimaatbeheerstelsel wat konstante gerief en veiligheid in alle openbare areas waarborg.

● Groot Woon- en Gemeenskapsprojekte
Villas en Stadswoninge: 'n Al-in-een-oplossing vir huishoudelike verhitting, verkoeling en warmwater wat algehele woongerief en -kwaliteit grootliks verbeter.
Residentiële Gemeenskappe: Ondersteun parallelle netwerke vir meervoudige eenhede om streeksgewyse skoonenergie-gesentraliseerde verhittingsstelsels te realiseer.
● Gespesialiseerde Skenarios
Seisoenale Termiese Stoorprojekte: Pas aan by langtermyn-bedryf by lae temperature, en benut sonkrag en ander hernubare energiebronne doeltreffend.
Verbeteringsprojekte: Vervang tradisionele ketels en lugversorgingsapparate sonder groot pyplynveranderinge, wat vinnige en gladde laag-koolstof-energie-opgraderings moontlik maak.