Get in touch

Heating and cooling Heat Pump

Home >  Products >  Heat Pump >  Heating and cooling Heat Pump

Micoe R290 Plus Series DC Inverter All-in-One Heat Pump for Heating, Cooling, and DHW(4kW-18kW)

Functions:
Heating & Cooling and DHW

Micoe R290 Plus Series new‑generation DC inverter monoblock heat pump for heating, cooling & DHW. 4kW‑18kW, R290 refrigerant (GWP=3), A+++ energy class, max 80°C water outlet, ‑25°C stable operation, WiFi/OTA smart control, SG Ready & Modbus RS485.

Certifications:

CE · KEYMARK· SG Ready · ErP · RoHS

Features:

R290 refrigerant, GWP=3
Energy class:A+++
Full DC inverter technology, operation down to -25°C
Outlet water temperature up to 80°C
WiFi control with Smart IOT and OTA support
Multi-language operation
Low noise operation
SG Ready Function
Power Detection Function
5-Inch TFT True Color Screen
Dual Temperature Zone
Reserved RS485 Communication Port
Customizable Heating Curve

1.Product Overview
Micoe R290 Plus Series is a new‑generation DC‑inverter monoblock heat pump for heating, cooling and domestic hot water (DHW). Unlike split‑type units requiring field refrigerant piping between indoor and outdoor sections, the monoblock design encloses the complete refrigeration circuit inside the outdoor unit and connects to buildings via water pipes. It simplifies installation, cuts commissioning time and eliminates on‑site refrigerant‑leak risks. Available in 10 models with single‑phase and three‑phase options, it delivers 4kW‑18kW heating capacity, ideal for homes, villas, apartments and light‑commercial projects.

2. R290 Eco‑Friendly Refrigerant | A+++ Top Energy Efficiency
R290 Plus employs R290 refrigerant with an ultra‑low GWP of 3. Boasting zero ozone‑depletion potential and superior thermodynamic performance for high efficiency, R290 ranks among the market’s most sustainable refrigerants. It complies with EU F‑Gas regulations and global green‑building standards, exempt from fluorinated‑gas restrictions in many territories.
The unit achieves the highest A+++ rating under EU ErP requirements. Its SCOP reaches 5.33 at 35°C water outlet under average climate conditions, and retains A+++ classification with SCOP up to 4.03 even at 55°C outlet temperature — benchmark performance within its product class.
For buyers, A+++ efficiency means lower end‑user operating expenses, better access to government subsidies and stronger bidding advantages for project tenders.

3. Max 80°C Water Outlet | Dual‑Temperature‑Zone Control
Standard heat pumps typically top out at 55‑60°C outlet temperature, while R290 Plus reaches up to 80°C. Compatible with traditional radiators as well as underfloor heating and fan coils, it enables seamless retrofits of existing buildings that demand high‑temperature hot water. Aligned with the EU Renovation Wave targeting 35 million building retrofits by 2030 as Europe phases out fossil‑fuel boilers, this unit serves as an optimal replacement for gas and oil‑fired boilers.
Dual‑zone temperature control sets independent temperatures for different heating circuits — e.g. 35°C for underfloor heating, 55°C for radiators — so each system operates at peak efficiency.
For B‑sector customers: the 80°C high‑temperature capability unlocks large retrofit markets beyond new constructions. One unit handles heating, cooling and DHW, streamlining system layout, reducing hardware count and lowering total installation costs.

4. Full DC Inverter | Stable Operation at ‑25°C
Instead of frequent full‑power start‑stop cycles, R290 Plus continuously adjusts compressor speed to match real‑time heating demand. This avoids energy waste, maintains precise temperature control and extends compressor service life.
Reliable performance down to ‑25°C ambient temperature fits Northern and Eastern European regions with frigid winters. The factory‑sealed monoblock refrigeration circuit prevents performance drop‑offs caused by on‑site refrigerant‑pipe work.

5. Floating Compressor Chamber | Ultra‑Quiet 35dB(A)
Featuring an independent floating compressor chamber and six‑point suspension damping system, R290 Plus physically isolates the compressor from airflow and cabinet vibration. Combined with multi‑layer sound‑absorbing materials and reinforced metal shielding, operating noise drops to 35dB(A) measured at 1‑meter distance — quieter than a library. Well‑suited for noise‑sensitive residences and hotels, it minimizes end‑user noise complaints and supports installation near bedrooms and residential zones.

6. Smart Control & OTA Updates
R290 Plus comes standard with a 5‑inch TFT touchscreen controller and built‑in WiFi. The mobile APP enables remote monitoring, temperature adjustment, timer configuration and real‑time energy‑consumption tracking.
Core Smart Functions
- SG Ready: Optimizes operation during low‑tariff grid periods to cut energy costs
- OTA Updates: Remote firmware upgrades, no on‑site service required
- Modbus RS485: BMS integration for centralized management of multi‑unit installations
- Multi‑language Support: 20+ languages for worldwide deployment
- Real‑time Energy Monitoring: Tracks power consumption to optimize system performance

7.About Micoe
Micoe (Stock Code: 603366) is a Shanghai A‑share listed enterprise, Global Top 500 New‑Energy Company, strategic partner of China Aerospace and official partner of China’s North‑South Polar Expeditions. Micoe heat‑pump units have been deployed at China’s Great Wall Antarctic Station aboard the research vessel *Xuelong 2*, representing the world’s first heat‑pump solution operating in Antarctica.
With 27‑years of clean‑energy expertise, Micoe runs 5 manufacturing bases spanning over 800,000 ㎡, with annual output above 1.7 million units. We have completed over 24,000 clean‑energy projects globally. 95% of key components are produced in‑house for full‑supply‑chain quality assurance. Standard lead time: 25 days. OEM & ODM services are available.
R290 Plus holds full global‑market certifications: CE, ErP, RoHS, SG Ready and A+++ energy rating, satisfying subsidy requirements across European countries. It also carries KEYMARK certification complying with EN14511 heat‑pump standards.
Our heat pumps are exported to 100+ countries and regions, supported by overseas‑warehouse spare‑part stock. Warranty: 3‑year full‑unit coverage, 5‑year extended warranty for the core compressor. Micoe engineering teams conduct minimum four overseas field visits each year for on‑site technical support and client visits, alongside 7×24‑hour remote technical assistance.

Power supply V/Ph/Hz 220-240/1/50 380-415/3/50
Heating  A7W35 Rated Heating Capacity kW 4.50  6.00  8.00  12.00  15.00  18.00  8.00  12.00  15.00  18.00 
 Rated Power Input kW 0.84  1.19  1.50  2.52  2.99  3.79  1.53  2.55  3.02  3.82 
COP w/w 5.36  5.04  5.33  4.76  5.02  4.75  5.23  4.71  4.97  4.71 
Heating  A7W55 Rated Heating Capacity kW 4.50  6.00  8.00  12.00  15.00  18.00  8.00  12.00  15.00  18.00 
 Rated Power Input kW 1.31  1.90  2.40  3.75  4.48  5.61  2.43  3.78  4.51  5.64 
COP w/w 3.44  3.16  3.33  3.20  3.35  3.21  3.29  3.17  3.33  3.19 
Cooling A35W7 Rated Cooling Capacity kW 4.00  6.00  8.00  11.80  14.50  16.00  8.00  11.80  14.50  16.00 
 Rated Power Input kW 1.22  1.82  2.56  3.85  4.71  5.37  2.59  3.88  4.74  5.40 
EER w/w 3.28  3.30  3.13  3.06  3.08  2.98  3.09  3.04  3.06  2.96 
Cooling A35W18 Rated Cooling Capacity kW 4.10  6.00  9.80  11.80  16.00  18.00  9.80  11.80  16.00  18.00 
 Rated Power Input kW 0.90  1.20  2.14  2.67  3.19  3.85  2.17  2.70  3.22  3.88 
EER w/w 4.56  5.00  4.58  4.43  5.02  4.68  4.52  4.38  4.97  4.64 
SCOP Average climate, W35°C kWh/kWh 5.21 5.31  5.33  5.21  5.09  4.91  5.28  5.11  4.95  4.93 
% 205  209  210  205  201  193  208  201  195  194 
/ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Average climate, W55°C kWh/kWh 3.93 3.93  3.97  3.99  4.03  3.99  3.90  3.99  3.95  3.90 
% 154  154  156  157  158  157  153  157  155  153 
/ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Operating temperature range (heating mode)
Ambient temperature range -25~35 -25~35 -25~35 -25~35 -25~35 -25~35 -25~35 -25~35 -25~35 -25~35
Water outlet temperature range 20~80 20~80 20~80 20~80 20~80 20~80 20~80 20~80 20~80 20~80
Operating temperature range (cooling mode)
Ambient temperature range 15~45 15~45 15~45 15~45 15~45 15~45 15~45 15~45 15~45 15~45
Water outlet temperature range 5~25 5~25 5~25 5~25 5~25 5~25 5~25 5~25 5~25 5~25
Operating temperature range (hot water)
Ambient temperature range -25~45 -25~45 -25~45 -25~45 -25~45 -25~45 -25~45 -25~45 -25~45 -25~45
Water outlet temperature range 20~70 20~70 20~70 20~70 20~70 20~70 20~70 20~70 20~70 20~70
ErP sound power level Average climate, W35°C dB(A) 50 49  50  50  54  55  50  50  54  55 
Average climate, W55°C dB(A) 51 50  51  51  55  56  51  51  55  56 
Sound pressure (1m) Average climate, W35°C dB(A) 37 35  35  35  39 40  35  35  39 40 
Average climate, W55°C dB(A) 38 36  36  36  40  41  36  36  40  41 
Max.input power kW 2.1 3.5 5.5 6.2 7.8 8.5 6.9 7.7 9.4 10.4
Max.input current A 9 15  24  27  34  37  10  11  14  15 
Refrigerant TYPE/(GWP) / R290(3) R290(3) R290(3) R290(3) R290(3) R290(3) R290(3) R290(3) R290(3) R290(3)
Charged volume kg 0.65 0.65  1.10  1.10  1.50  1.50  1.10  1.10  1.50  1.50 
Water side connection Inch G1 G1 G1 G1 G1-1/4 G1-1/4 G1 G1 G1-1/4 G1-1/4
Water Pressure Drop kPa 15 15  15  20  20  25  15  20  20  25 
Operation Pressure(Low Pressure Side) MPa 0.8
Operation Pressure(High Pressure Side) MPa 3
Maximum Allowable Pressure MPa 3.4
Min/Max Water Pressure   MPa 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3 0.1/0.3
Rated Water Flow  m³/h 0.77 1.00  1.40  2.06  2.58  3.10  1.40  2.06  2.58  3.10 
Net Dimensions ( L×W×H ) mm 1100×438×660 1220×458×865 1320×478×913 1320×478×913 1187×488×1456 1187×488×1456 1320×478×913 1320×478×913 1187×488×1456 1187×488×1456
Packing dimensions  ( L×W×H ) mm 1155×485×806 1250×493×1010 1352×533×1055 1352×533×1055 1217×538×1598 1217×538×1598 1352×533×1055 1352×533×1055 1217×538×1598 1217×538×1598
Net Weight kg 83 110  162  162  205  205  169  169  212  212 
Gross weight kg 98 125  182  182  225  225  189  189  232  232

🏠Residential – Single-family homes, villas, apartments
🏨Hotels – Heating, cooling, and DHW for guest rooms and common areas
🏢Office Buildings – Space heating, cooling, and sanitary hot water
🏫Schools – Heating, cooling, and DHW for campuses
🏗️Retrofit Projects – Compatible with radiator systems, no major renovation required

📞Contact Us

Ready to specify the Micoe R290 Plus heat pump for your project? Contact our sales team now for a custom‑tailored solution.
To receive your bespoke proposal, please provide the following information:
‑ Project type (residential, hotel, office building, school, etc.)
‑ Building area or heating load requirement
‑ Local climate conditions
‑ Power supply (single‑phase / three‑phase)

Online Inquiry

If you have any suggestions, please contact us

Contact Us